The day-to-day application requirements in a corporate world that can be achieved using Utility Programs are illustrated below:
1. A file has 100 records. The first 10 records need to be written to output file.
//JSTEP020 EXEC PGM=ICETOOL //TOOLMSG DD SYSOUT=* //DFSMSG DD SYSOUT=* //IN1 DD DSN=MYDATA.URMI.STOPAFT,DISP=SHR //OUT1 DD SYSOUT=* //TOOLIN DD * COPY FROM(IN1) TO(OUT1) USING(CTL1) /* //CTL1CNTL DD * OPTION STOPAFT=10 /*
The option STOPAFT will stop reading the input file after 10th record and terminates the program. Hence, 10 records are written to output.
2. Input file has one or more records for same employee number. Write unique records to output.
//STEP010 EXEC PGM=SORT //SYSOUT DD SYSOUT=* //SORTIN DD DSN=MYDATA.URMI.DUPIN,DISP=SHR //SORTOUT DD SYSOUT=* //SYSIN DD * SORT FIELDS=(1,15,ZD,A) SUM FIELDS=NONE /*
SUM FIELDS=NONE removes duplicates on fields specified in SORT FIELDS. In the above example, employee number is in the field position 1,15. The output file will contain the unique employee numbers sorted in ascending order.
3. Overwrite input record content.
//JSTEP010 EXEC PGM=SORT //SORTIN DD DSN= MYDATA.URMI.SAMPLE.MAIN,DISP=SHR //SORTOUT DD SYSOUT=* //SYSPRINT DD SYSOUT=* //SYSOUT DD SYSOUT=* //SYSIN DD * OPTION COPY INREC OVERLAY=(47:1,6) /*
In the input file, the content in position 1,6 is overwritten to the position 47,6 and then copied to the output file. INREC OVERLAY operation is used in order to rewrite data in input file before copying to output.
4. Adding a sequence number to the output file.
//JSTEP010 EXEC PGM=SORT //SORTIN DD * data1 data2 data3 /* //SORTOUT DD SYSOUT=* //SYSPRINT DD SYSOUT=* //SYSOUT DD SYSOUT=* //SYSIN DD * OPTION COPY BUILD=(1:1,5,10:SEQNUM,4,ZD,START=1000,INCR=2) /*
The output will be:
data1 1000 data2 1002 data3 1004
4-digit sequence number is added in output at position 10, starting at 1000 and incremented by 2 for every record.
5. Adding Header/Trailer to output file.
//JSTEP010 EXEC PGM=SORT //SORTIN DD * data1 data2 data3 /* //SORTOUT DD SYSOUT=* //SYSPRINT DD SYSOUT=* //SYSOUT DD SYSOUT=* //SYSIN DD * SORT FIELDS=COPY OUTFIL REMOVECC, HEADER1=(1:C'HDR',10:X'020110131C'), TRAILER1=(1:C'TRL',TOT=(10,9,PD,TO=PD,LENGTH=9)) /*
The output will be:
HDR 20110131 data1 data2 data3 TRL 000000003
TOT calculates the number of records in the input file. HDR and TRL are added as identifiers to header/trailer, which is user defined and can be customised as per the users' needs.
6. Conditional Processing
//JSTEP010 EXEC PGM=SORT //SORTIN DD * data1select data2 data3select /* //SORTOUT DD SYSOUT=* //SYSPRINT DD SYSOUT=* //SYSOUT DD SYSOUT=* //SYSIN DD * INREC IFTHEN=(WHEN=(6,1,CH,NE,C' '),BUILD=(1:1,15), IFTHEN=(WHEN=(6,1,CH,EQ,C' '),BUILD=(1:1,5,7:C'EMPTY ') OPTION COPY /*
The output will be:
data1select
data2 EMPTY
data3select
Based on the 6th position of the file, the BUILD of output file varies. If 6th position is SPACES, then text "EMPTY" is appended to input record. Else, the input record is written to output, as-is.
7. Backing up a file
//JSTEP001 EXEC PGM=IEBGENER //SYSPRINT DD SYSOUT=* //SYSIN DD * //SYSOUT DD SYSOUT=* //SORTOUT DD DUMMY //SYSUT1 DD DSN=MYDATA.URMI.ORIG,DISP=SHR //SYSUT2 DD DSN=MYDATA.URMI.BACKUP,DISP=(NEW,CATLG,DELETE), // DCB=*.SYSUT1,SPACE=(CYL,(50,1),RLSE)
IEBGENER copies the file in SYSUT1 to file in SYSUT2. Please note that file in SYSUT2 takes the same DCB as that of the SYSUT1 in the above example.
8. File Comparison
//STEP010 EXEC PGM=SORT //MAIN DD * 1000 1001 1003 1005 //LOOKUP DD * 1000 1002 1003 //MATCH DD DSN=MYDATA.URMI.SAMPLE.MATCH,DISP=OLD //NOMATCH1 DD DSN=MYDATA.URMI.SAMPLE.NOMATCH1,DISP=OLD //NOMATCH2 DD DSN=MYDATA.URMI.SAMPLE.NOMATCH2,DISP=OLD //SYSOUT DD SYSOUT=* //SYSIN DD * JOINKEYS F1=MAIN,FIELDS=(1,4,A) JOINKEYS F2=LOOKUP,FIELDS=(1,4,A) JOIN UNPAIRED,F1,F2 REFORMAT FIELDS=(?,F1:1,4,F2:1,4) OPTION COPY OUTFIL FNAMES=MATCH,INCLUDE=(1,1,CH,EQ,C'B'),BUILD=(1:2,4) OUTFIL FNAMES=NOMATCH1,INCLUDE=(1,1,CH,EQ,C'1'),BUILD=(1:2,4) OUTFIL FNAMES=NOMATCH2,INCLUDE=(1,1,CH,EQ,C'2'),BUILD=(1:2,4) /*
- JOINKEYS specifies the field on which the two files are compared.
- REFORMAT FIELDS=? places 'B' (matched records), '1' (present in file1, but not in file2), or '2' (present in file2 but not in file1) in the 1st position of the output BUILD.
- JOIN UNPAIRED does a full outer join on the two files.
The output will be:
MATCH File 1000 1003 NOMATCH1 File 1001 1005 NOMATCH2 File 1002
The same functionality can be achieved using ICETOOL also.
No comments: